Manual pressurization skid - MODEL SKMM-100/GAS/B2
Hydraulic/pneumatic pressurization skid. Controlled by electrical pushbutton on a graphical synoptic panel or manual needle valves (GAS). Every process element is controlled directly by the operator; main safety garrison for wrong maneuvers has been included. This make the SKID very flexible to any testing procedure. Leak could be measured (option) by electronic bubbles counter, high accuracy water column (API) , turbine flow meter and mass flow meter (FCI 70-2) . Vacuum pump could be installed (option) to assure the absence of air inside valve's body before filling it with water; in order to reduce test time and increase operator's safety. All wet process components are stainless steel made and dimensioned for a working pressure of 700 bar (1200/2100 bar as option). It has a high filling flow ability and the recovering of test fluid is automatic. Metal to metal needle valves assure high reliability. A PC windows based for data recording could be included, instrumentation supplied with MODBUS serial interface protocol (TestREC2.0-M).

| Max working pressure | |
| H2O | - |
| N2 | 200 / 450 / 700 / 1000 barbar |
| Air | 200 / 450bar |
| Min working pressure | |
| H2O | 3,5bar (0.5 bar as optional) |
| N2 | 10bar |
| Air | 0.5bar (30 mbar as optional) |
| Filling flow | - |
| Vacuum pump | - |
| DBB test opt. | Available |
| GAS Test opt. | Available |
| GAS Booster opt. | Available |
| CAVITY test opt | - |
| Multistation opt. | - |
| Actuator control panel opt. | - |
| ATEX certification opt. | Available |
| Process valves | "Metal to Metal" needle valve |
| Process style | Unidirectional |
| Fluid allowed | Water, Water & oil mixture, Glicole, Ethanol (Atex), Methanol (Atex), GAS (N2, He, AIR) |
| Control system | Manual needle valve |
| Pressure measure | 4-20mA Pressure transmitter+ 7-seg Digital Display |
| Temperature measure | - |
| Ref. Standard | API \ DIN \ BS \ FCI |
| Serial Interface | RS485 MODBUS PROTOCOL |
| Certification software | TestREC3.0-M |
| Leakage detection | |
| Air/GAS | ANSI Bubbler, Bubbles counter, Volumetric bubbler, Mass flowmeters |
| Water | - |
| Process Connections | NPT 1/2"-F, HP 1/4" |
| Service air supply | - |
| Electrical supply | 2Ph+T 220V@50Hz 1KWOther available on request. |
| Dimensions | 600(L) x 800(P) x 1580(H) |
HORIZONTAL test bench
VERTICAL test benches
Multiple stations test benches
Water immersion GAS test benches
PSV test benches
Skid
Special applications
40 CT LAB