Multiple stations test benches
MODEL BV-5MV/20
Vertical test rig with universal clamping style:
-Claws on RF/RJ valves
-Press clamping
-Inner radial seal.
5 test places available for multiple pressure tests.
The screwed columns assure complete absence of external forces on valve body.
This prerogative makes it compliant to the most widespread international test standards.
The upper side reaction bridge can be removed with a 90° rotation flag style.
In this way loading procedures are easier.
Water recovering is automatic even for check valves.
A device to open check valves is available on request.
The rig is controlled by a SKA-100 pressurization skid; to have more information about it please consult dedicated technical data sheets.
The rig could be completed with several options and accessories, please contact our sales office to have more information.
-Claws on RF/RJ valves
-Press clamping
-Inner radial seal.
5 test places available for multiple pressure tests.
The screwed columns assure complete absence of external forces on valve body.
This prerogative makes it compliant to the most widespread international test standards.
The upper side reaction bridge can be removed with a 90° rotation flag style.
In this way loading procedures are easier.
Water recovering is automatic even for check valves.
A device to open check valves is available on request.
The rig is controlled by a SKA-100 pressurization skid; to have more information about it please consult dedicated technical data sheets.
The rig could be completed with several options and accessories, please contact our sales office to have more information.
* Working limits for SHELL TEST with INNER RADIAL SEAL and PROPORTIONAL PRESS CLAMPING
DN | 50'' | 100'' | 125'' | 150'' | 200'' | ||||||||
PN-10 | TON | ||||||||||||
PN-16 | TON | ||||||||||||
PN-25 | TON | ||||||||||||
PN-40 | TON | ||||||||||||
PN-64 | TON | ||||||||||||
PN-100 | TON |
Reaction force | 5x20TON |
Length max | 340mm |
Length min | 50mm |
Max flange diameter | 300mm |
Basement water vessel | 100 Liters ca. |
Terminations allowed | BW, SW, RF, RJ |
Clamping style | Type 2 – Bore plugs |
Dimensions (mech) | 1200 (L) x 1490 (D) x 1950/2305 (H) |