MODEL BO30-2CV/40SH

BORE PLUGS OR COMBINED CLAMPING STYLES AVAILABLE.
FULL PROTECTION SHIELD DOUBLE ACCESS SIDE

Horizontal test benches available in two different clamping style: Bore plugs or combined. The mobile reaction bridge is moved by one screwed column that assures the complete absence of external forces on valve body.
This prerogative makes it conform to the most diffuse international test standards (bore plugs).
A BULLETS PROOF full protection is foreseen to perform high pressure gas/water test in high safety conditions. Door opening is conditioned by visual inspection rules (automatic pressure reducing before inspection) and normal pressure discharge procedure.
In the basement, a water tank is installed as water reservoir for test procedures. Test process is controlled by electronic PLC & LCD touch screen. Double control AUTO / MAN software is foreseen to give maximum flexibility to operator.Test data can be printed out on 24cln thermal printer directly in test area or be downloaded by serial connection (standard) to Windows based PC with TestREC6.6.0 certification software.

Working limits for PRESS CLAMPING and INNER RADIAL SEAL
   
DN. ½"" 1" 2" 3" 4" 5" 6" 8"
ANSI-150                
ANSI-300                
ANSI-600                
ANSI-900                
ANSI-1500                
ANSI-2500                
ANSI-4500                
Valve test bench, banchi di prova per valvole, test rig - MODEL BO30-2CV/40SH
AVAILABLE UP TO 100 TON
AVAILABLE UP TO 12

(*)Note: Indicated values have been calculated for shell test and with API-6D nominal minimum bore size + 30mm and they have to be considered as reference only.
For more accurate information please contact our technical office or consult instructions book delivered along the rig.



Reaction force 40 TON (see working limits table)
Length min - max 0 - 550 mm
Max valve height 900 mm
Columns inner distance 550 mm
Flow axes height 830 mm
Basement water tank 100 Liters
Termination allowed RF, RTJ, BW, SW
Clamping style Type 3 – combined
Reference standards ISO, DIN, API, ANSI, ASTM, FCI, BS
(Other on request).
Filling Flow 70L/min
Vacuum pump 40m /h (Option)
Standard flow meter Digital Bubbles Counter
& Digital water column
Max pressure 4000 bar (water) - 1050 bar (gas)
Pneumatic supply 6.5 bar @ 1100 Nl/min
Electric supply 3PH + T, 400V@50Hz, 5KW
(other on request)
Dimensions 3500(L) x 1100(P) x 1600(H)