Vertical test benches
MODEL BV-PMC/500
Vertical test rig with proportional pressing clamp; the press force is controlled automatically according to the water pressure inside valve, and the result load is reduced to minimal terms.
Mobile upper side bridge allow vertical loading of the valve and the possibility to have double working stand; while the first is working, the second could be prepared for next piece. In the basement there is a water tank and an external water tank could be add as option. The use of a opened castle as upper side reaction structure, allow the user to make visual inspection of valve seat during the test.
The rig is controlled by SKA-100 pressurization skid; to have more information about please consult dedicated technical data sheets. The rig could be completed with several options and accessories, please contact our sales office to have more information.
Mobile upper side bridge allow vertical loading of the valve and the possibility to have double working stand; while the first is working, the second could be prepared for next piece. In the basement there is a water tank and an external water tank could be add as option. The use of a opened castle as upper side reaction structure, allow the user to make visual inspection of valve seat during the test.
The rig is controlled by SKA-100 pressurization skid; to have more information about please consult dedicated technical data sheets. The rig could be completed with several options and accessories, please contact our sales office to have more information.
ANSI | |||||||||
DN. | 600 | 700 | 800 | 900 | 1000 | 1200 | 1300 | 1400 | |
PN-10 | |||||||||
PN-16 | |||||||||
PN-25 | |||||||||
PN-40 | |||||||||
PN-64 |
Reaction force | 500 TON (see working limits table) |
Working stand | 1 ( 2 on request) |
Allowed size | DN600/DN1400, PN16/PN64 |
Valve length max | (A) 1140 mm |
Valve length min | (B) 200 mm |
Column inner distance | (C) 1750 mm |
Loading plate height | (D) 1000 mm |
Bridge course | E) 850 mm |
Cylinder | Ø430/300, course 430 mm |
Basement water tank c. | 220 Liters |
Terminations allowed | RF, RJ |
Clamping style | Type 1 – Proportional Compression (flange surface). |
Clamping force control | Automatic within 5..100% interval, proportional to the hydrostatic pressure inside the valve under test. |
Reference standards | ISO, DIN, API, ANSI, ASTM, FCI, BS (Other on request). |
Pneumatic supply | 6.5 bar @ 1100 Nl/min Dry air not lubricated |
Electric supply | 3PH + T, 380V@50Hz, 9.65KW (11.15 KW with vacuum pump) |
Dimensions | 2300(L) x 2000(P) x 2800(H) |